serial_over_lan_connection_issues

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
serial_over_lan_connection_issues [2018/11/29 16:27] – [Console dropped due to BP Com Request Error] walkeradminserial_over_lan_connection_issues [2023/03/09 22:35] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ====== Serial over LAN connection issues ====== ====== Serial over LAN connection issues ======
 <color darkorange>Nov 2018</color> <color darkorange>Nov 2018</color>
-\\  
-\\  
- 
-<color #ed1c24>THIS SECTION IS NOT COMPLETE</color> 
-\\  
 \\  \\ 
 \\  \\ 
Line 62: Line 57:
 Above we can see the Serial Over LAN port selection. When you are connected to the T1 via a Serial Console connection, you can use the following command: Above we can see the Serial Over LAN port selection. When you are connected to the T1 via a Serial Console connection, you can use the following command:
 \\  \\ 
-    ctrl g no+    ctrl g number
 \\  \\ 
 \\  \\ 
Line 69: Line 64:
 \\  \\ 
     ctrl g 1     ctrl g 1
 +    
 +    Remember
 +    ctrl-g 0 is the switch
 +    ctrl-g 1-9 are the sleds
 \\  \\ 
 \\  \\ 
Line 77: Line 76:
 \\  \\ 
 \\  \\ 
-<color #ed1c24>ctrl gg</color> 0/1/2 will connect you to either the (0) BCM, (1) Server1 or (2) Server2.+<color #ed1c24>ctrl gg 0/1/2</color> will connect you to either the (0) BCM, (1) Server1 or (2) Server2.
 \\  \\ 
 \\  \\ 
Line 96: Line 95:
 \\  \\ 
 \\  \\ 
-The error <color #ed1c24>Console dropped due to BP Com Request</color> means that the BMC cannot be contacted. To fix this we need to connect to the BMC via another means (normally it's IP Address and SSH).+The error <color #ed1c24>Console dropped due to BP Com Request</color> means that the BMC cannot properly be contacted. To fix this we need to connect to the BMC via serial. Although the serial over LAN is not working, you should still be able to connect to the BMC using <color #ed1c24>ctrl-g 'sled number'</color> 
 +\\  
 +\\  
 +You might have to toggle between the BCM and Payload a couple of times to get the BCM to respond (ctrl gg 0, then ctrl gg 1, then ctrl-gg 0and keep hitting enter until you get a response.
 \\  \\ 
 \\  \\ 
-SSH to the BMC, and from the command line run the following command:+Once connected to the BMC, and from the command line run the following command:
 \\  \\ 
     mc reset cold     mc reset cold
serial_over_lan_connection_issues.1543508842.txt.gz · Last modified: 2023/03/09 22:35 (external edit)