dual_output_el_switch_on_loss_of_all_output_interfaces [2024/05/23 16:47] – [Remove Dual Output Prevention from EL] walkeradmin | dual_output_el_switch_on_loss_of_all_output_interfaces [2024/05/23 16:50] – [Remove Dual Output Prevention from EL] walkeradmin | ||
---|---|---|---|
Line 22: | Line 22: | ||
{{ : | {{ : | ||
\\ | \\ | ||
- | From the | + | From the General tab on the Encoder, untick Dual Output Prevention. |
+ | \\ | ||
+ | \\ | ||
+ | In a 1+1 EL configuration, | ||
+ | \\ | ||
+ | \\ | ||
+ | This causes an issue because there is a short period of time where neither Encoder is outputting, While the time for this condition is very short, it is long enough that the active Mux will have no inputs from either Encoder, and the active Mux will switch to the backup. Disabling DOP on the Encoders will stop this happening. | ||
+ | \\ | ||
+ | \\ | ||
+ | ---- | ||
+ | ==== ==== |