Nov 2023


Introduction

It has been quite some number of years since I dealt with Modulators and Receivers, so I did struggle a little with this recently, these are some notes of the values I used, just to get a Mod/Demod setup going.


Hardware Connections

See below for the connection method between the AVP and the RX1.


The Monitor F-Type output of the AVP is connected directly to the RF input of the RX1 (RX4 is on the left). There is no up-convertor or attenuator in use.


AVP Output Parameters

Below is the output settings I used on the AVP Modulator.


Output Parameters

RF Carrier ID State On (don't confuse this with Modulation on) Output Select L-Band Output State On Reduced Power (we don't want to overload the RX1 input) Output Power-up State (Last State)

L-Band Output

Frequency Input Mode L-Band Frequency L-Band Frequency 1070 MHz Reduced L-Band Line-up Power -5 Nominal L-Band Power -10 L-Band Spectrum Sense Inverted L-Band Tilt 0 L-Band Up-converter Frequency 2500 MHz Upconverter Power Off Upconverter Reference Off