dual_output_el_switch_on_loss_of_all_output_interfaces [2024/05/23 17:46] walkeradmindual_output_el_switch_on_loss_of_all_output_interfaces [2024/05/23 17:49] – [nCompass Changes] walkeradmin
Line 114: Line 114:
 \\  \\ 
 \\  \\ 
 +----
 === nCompass ServerCoreService.exe.config === === nCompass ServerCoreService.exe.config ===
 \\  \\ 
Line 119: Line 120:
 \\  \\ 
   C:\Program Files (x86)\MediaKind\nCompass Control\Bin   C:\Program Files (x86)\MediaKind\nCompass Control\Bin
-\\ +  
 Open this file and find the following line (around line 31) Open this file and find the following line (around line 31)
 \\  \\ 
   <add key="RedundancySwitchNearestDeviceFirst" value="false"/>   <add key="RedundancySwitchNearestDeviceFirst" value="false"/>
-\\ +
 By default, it will be set to 'false' change this to 'true' and save the file. By default, it will be set to 'false' change this to 'true' and save the file.
 +\\ 
 +\\ 
 +Restart the Windows Service 'Mediakind - Server Core'
 +\\ 
 +\\ 
 +
 +
 +
 +
 +<file>
 +<!-- In the event of an input alarm this setting controls whether redundancy
 +    will switch the furthest upstream device first (when set to false) or
 +    switch the nearest upstream device first (when set to true). Nearest and
 +    furthest are with respect the device that raised the input alarm.
 +</file>