dual_output_el_switch_on_loss_of_all_output_interfaces [2024/05/23 17:44] walkeradmindual_output_el_switch_on_loss_of_all_output_interfaces [2024/05/23 17:45] – [test] walkeradmin
Line 112: Line 112:
 \\  \\ 
 {{ :restart_alam_handler_service.png?800 |}} {{ :restart_alam_handler_service.png?800 |}}
-==== test ====+=== nCompass ServerCoreService.exe.config === 
 + 
 +\\  
 +\\  
 +In the same folder as the AlarmHandlerService.exe.config file is the ServerCoreService.exe.config file. 
 +\\  
 +  C:\Program Files (x86)\MediaKind\nCompass Control\Bin 
 +\\  
 +Open this file and find the following line (around line 31) 
 +\\  
 +\\  
 +  <add key="RedundancySwitchNearestDeviceFirst" value="false"/> 
 +\\  
 +By default, it will be set to 'false' change this to 'true' and save the file.