+ | ==== Introduction ==== | ||
Okay, it's a long title, but what does it mean? If we look at the nCompass map below, we can see that the Encoders are outputting, but only a single interface is show, even though we are outputting on two interfaces (eno3 and eno4) | Okay, it's a long title, but what does it mean? If we look at the nCompass map below, we can see that the Encoders are outputting, but only a single interface is show, even though we are outputting on two interfaces (eno3 and eno4) | ||
\\ | \\ | ||
- | {{ : | + | \\ |
+ | {{ : | ||
+ | \\ | ||
+ | when using dual outputs, if either output fails, we get a <color # | ||
+ | \\ | ||
+ | \\ | ||
+ | ---- | ||
+ | ==== Remove Dual Output Prevention from EL ==== | ||
+ | \\ | ||
+ | If you are using DOP (dual output prevention) in the Encoders, you need to turn this off. | ||
+ | \\ | ||
+ | \\ | ||
+ | {{ : | ||
+ | \\ | ||
+ | From the General tab on the Encoder, untick Dual Output Prevention. | ||
+ | \\ | ||
+ | \\ | ||
+ | In a 1+1 EL configuration, | ||
+ | \\ | ||
+ | \\ | ||
+ | This causes an issue because there is a short period of time where neither Encoder is outputting, While the time for this condition is very short, it is long enough that the active Mux will have no inputs from either Encoder, and the active Mux will switch to the backup. Disabling DOP on the Encoders will stop this happening. | ||
+ | \\ | ||
+ | \\ | ||
+ | ---- | ||
+ | ==== ==== |
dual_output_el_switch_on_loss_of_all_output_interfaces.txt · Last modified: 2024/05/24 10:13 by walkeradmin